Ions that react with Ag+can be determined electrogravimetrically by deposition on a silver working anode:

Ag(s)+X-AgX(s)+e-

(a) What will be the final mass of a silver anode used to electrolyze 75.00 mL of 0.02380 M KSCN if the initial mass of the anode is 12.4638 g?

(b) At what electrolysis voltage (versus S.C.E.) will AgBr(s) be deposited from 0.10M Br? (Consider negligible current flow, so that there is no ohmic potential, concentration polarization, or overpotential.)

(c) Is it theoretically possible to separate 99.99% of0.10M Klfrom0.10MKBr by controlled-potential electrolysis?

Short Answer

Expert verified
  1. The final mass of silver anode used in electrolysis is 12.5675 g .
  2. The voltage at which bromide ion deposits silver bromide 0.111 V.
  3. It is impossible to separate potassium iodide from potassium bromide.

Step by step solution

01

Introduction

  • Electrogravimetry is a technique for electroplating a metal onto a platinum electrode in a quantitative manner.
  • The difference in the weight of the electrode before and after electroplating determines the amount of metal plated.
02

Calculation regarding part (a)

(a)

It is necessary to calculate the mass of silver anode used in electrolysis.

To figure out: The weight of the silver anode used in electrolysis.

AgSCN concentration is the same as SCN concentration. The concentration of SCN can be calculated from the provided concentration of KSCN. SCN is computed as

75.00mLof0.02380MKSCN=1.785mmolSCN1.785mmolSCN=1.785mmolAgSCN1.785mmolAgSCNcontains0.1037gSCNMass=12.4638+0.1037=12.5675g

The amount of silver anode used in electrolysis is 12.5675g.

03

Calculation regarding part (b)

(b)

It is necessary to compute the voltage at which silver bromide deposits from bromide ions.

The voltage of a cell is stated as when the electric current is too smallE=E(cathode)-E(anode)

E(cathode) is the electrode potential that is connected to the current source's negative terminal.

E(anode) is the potential of an electrode that is connected to the positive terminal of a current source.

Voltage can override the activation energy of a process at an electrode, resulting in overpotential. Overpotential is the required voltage to apply.

Ohmic potential can be expressed as follows

Eohmic=IR

Concentration Polarization is the difference in concentration of products and reactants at the electrode's surface, as opposed to the same concentration in solution.

The voltage at which silver bromide deposited from bromide ions was determined.

At anode:AgBr((g))+e-Ag(s)+Br-E°=0.071V

E(cathode)=E(S.C.E.)=0.241VE(anode)=0.0710.05916logBr=0.0710.05916log[0.10]=0.130VE(cell)=E(cathode)E(anode)=0.111V

The voltage at which bromide ion deposits silver bromide 0.111 V.

04

Calculation regarding part (c)

(c)

It must be established whether potassium iodide and potassium bromide can be separated.

The constant for the solubility product (KspIn an aqueous solution, is defined as the equilibrium between a chemical and its ions.

The solubility product is the concentration of a dissolved ion multiplied by the power of coefficients.

a lonic substanceA3BKK(sp)=[A]3[B].

Ion-based product ( Qc) is defined as the product of the ion concentrations raised to the power of the ion coefficients in the solution. role="math" localid="1668358640049" Qc>Ksp, There will be precipitation.

Qcis lower than 0.10MK , In a solution with no precipitation, more solute can dissolve.

Qcis equal to Ksp.

In solution, no additional solutes can dissolve or precipitate.

To determine whether potassium iodide and potassium bromide can be separated.

In equilibrium with iodide, the intensity of silver ion is

[Ag+]=Ksp/[I-]=(8.3×1017)(1.0×10-3)=8.3×10-12M

When silver ions are in equilibrium with bromide ions, their strength is

[Ag+]=Ksp/[I-]=(5.0×10-15)0.10=5.0×10-12

Thus, role="math" localid="1668358876100" 8.3×1012NThe precipitation of silver ion begins 0.10M The bromide ion is a type of ion that exists in nature. There isn't going to be any rain.

It is impossible to separate potassium iodide from potassium bromide.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

A0.3268-gunknown containing Pb(CH3CHOHCO2)2(leadLactate, FM 385.3) plus inert material was electrolyzed to produce 0.1111gofPbO2(FM239.2). Was the PbO2deposited at the anode or at the cathode? Find the weight percent of lead lactate in theUnknown.

17-17. The experiment in Figure 17 - 9 required 5.32mA for 864s for complete reaction of a5.00 - mLaliquot of unknown cyclohexene solution.

(a) How many moles of electrons passed through the cell?

(b) How many moles of cyclohexene reacted?

(c) What was the molarity of cyclohexene in the unknown?

In 1MNNH3/1MNH4CIsolution,Cu2+is reduced toCu+near -0.3V(versus S.C.E.), andCu+is reduced toCu(inHg)near 0.6V.

(a) Sketch a qualitative sampled current polarogram for a solution ofCu+.

(b) Sketch a polarogram for a solution ofCu2+.

(c) Suppose that Pt, instead of Hg, were used as the working electrode. Which, if any, reduction potential would you expect to change?

cd2+was used as an internal standard in the analysis of Pb2+by square wave polarography. Cd2+gives a reduction wave at -0.60 V and Pb2+gives a reduction wave at –0.40 V. It was first verified that the ratio of peak heights is proportional to the ratio of concentrations over the whole range employed in the experiment. Here are results for known and unknown mixtures:

The unknown mixture was prepared by mixing 25.00(±0.05)mLof unknown (containing only Pb2+) plus 10.00(±0.05)mLof 3.23(±0.01)×10-4MCd2+and diluting to 50.00(±0.05)mL.

(a) Disregarding uncertainties, find [Pb2+]in the undiluted unknown.

(b) Find the absolute uncertainty for the answer to part (a).

(a) At what cathode potential will Sb(s)deposition commence from 0.010MSbO+solution at pH 0.00? Express this potential versus S.H.E. and versusAg|AgCI. (Disregard overpotential, about which you have no information.)

SbO++2H++3e-Sb(s)+H2OE°=0.208V

(b) What percentage of0.10MCu2+could be reduced electrolytically to Cu(s)before0.010MSbO+in the same solution begins to be reduced at pH 0.00?