The efficiency of a gas chromatography column is measured by a parameter called plate height (H, m m) , which is related to the gas flow rate (u, mL/min) by the van Deemter equation: H = A + B / u + Cu , where A , B , and C are constants. Prepare a spreadsheet with a graph showing values of as a function of u for u =4,6,8,10,20,20,40,50,60,70,80,90 and 10 mL/min. Use the values A = 1.65 m m , B = 25.8 m m .m L/min, and C = 0.023 6 m m.min/mL.

Short Answer

Expert verified

The spreadsheet and the graph are in step 2 and 3.

Step by step solution

01

The given equation and values

The following van Deemter equation will be used to create a spreadsheet with a graph showing the values of H as a function of u.

H = A + B / u + Cu

In this equation, A = 1.65 m m , B = 25.8 m m .m L/min, and C = 0.023 6 m m.min/mL

02

The list of values

The following H values are listed in the table below, and they are used to create a graph.

The above list is according to the values of H.

03

The graph of given equation

The graph for H = A + B / u + Cu van Deemter equation would be as follows:

The above graph is according to the value of H.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

What color do you expect to observe for the cresol purple indicator (Table 11-3) at the following pH values?

(a)1.0;(b)2.0;(c)3.0.

Control chart -- Volatile compounds in human blood serum were measured by purge and trap gas chromatography/mass spectrometry. For quality control, serum was periodically spiked with a constant amount of 1,2-dichlorobenzene and the concentration role="math" localid="1663334314380" (ng/g=ppb)was measured. Find the mean and standard deviation for the following spike data and prepare a control chart. State whether or not the observations (Obs.) meet each criterion for stability in a control chart.

Molecular mass by sodium dodecylsulfate–gel electrophoresis. Ferritin is a hollow iron-storage protein 74 consisting of 24 subunits that are a variable mixture of heavy (H) and light (L) chains,arranged in octahedral symmetry. The hollow center, with a diameter of 8 nm, can hold up to 4 500 iron atoms in the approximate form of the mineral ferrihydrite (5Fe1O3×9H2O)Iron(II) enters the protein through eight pores located on the threefold symmetry axes of the octahedron. Oxidation to Fe(III) occurs at catalytic sites on the H chains. Other sites on the inside of the L chains appear to nucleate the crystallization of ferrihydrite. Migration times for protein standards and the ferritin subunits are given in the table. Prepare a graph of log(molecular mass) versus 1/(relative migration time), where relative migration time 5 (migration time)/(migration time of marker dye). Compute the molecular mass of the ferritin light and heavy chains. The masses of the chains, computed from amino acid sequences, are 19 766 and 21 099 Da.

Write charge and mass balances for aqueous Ca3(PO4)2 if the species are Ca2+,CaOH+,CaPO4-,PO3-,HPO42-,H2PO4-,H3PO4.

How many grams of (FM 142.04) should be added to how many grams of sulfuric acid (FM 98.08) to give of buffer with pH 2.80 and a total sulfur concentration of ?

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.

Sign-up for free